It is an eight-channel battery analyzer for most applications in battery testing fields such as electrode materials research, battery performance & cycle test, small-scale battery formation, capacity ...
| Battery Testing System | |||||||||||
| Model: | BTS4000- | 5 | V | 6 | A | Battery Testing System | SN: | CT-4008Tn | -5V6A | -S1/164 | |
| Items | Values | ||||||||||
| Input AC | AC 220V/110V ±10% / 50Hz | ||||||||||
| Input power | 425 W | ||||||||||
| Resolution | AD:24bit; DA: 16bit | ||||||||||
| Input impedance | ≥1M Ω | ||||||||||
|
Voltage |
CV output range | 25mV~5V | |||||||||
| Min discharge voltage | 1V for universal holder,2M line length up to 1.5V | ||||||||||
| Accuracy | ± 0.05% FS | ||||||||||
| Stability | ± 0.05% FS | ||||||||||
|
Current |
Output range/channel | Range1: 0.5mA-0.1A; Range2: 0.1A-3A; Range3: 3A-6A | |||||||||
| Accuracy | ± 0.05% FS | ||||||||||
| CV cut-off current | Range1: 0.2mA; Range2: 6mA; Range3: 12mA | ||||||||||
| Stability | ± 0.05% FS | ||||||||||
|
Power |
Output power/channel | 30 | W | ||||||||
| Stability | ± 0.1% of FS | ||||||||||
|
Time |
Current response time | <1ms (10%FS~90%FS) | |||||||||
| Working step time | ≤(365*24)h/step Time format-00:00:00.000(h, m, s, ms) | ||||||||||
|
Data record |
Data record conditions | Min data record interval:100ms | |||||||||
| Min voltage change: 10mV | |||||||||||
| Min current change: Range1: 0.2mA; Range2: 6mA; Range3: 12mA | |||||||||||
| Frequency | 10Hz | ||||||||||
|
Charge |
Charge modes | CC, CV, CCCV, CP | |||||||||
| Cut-off condition | Voltage, Current, Time, Capacity, Energy, -△V | ||||||||||
|
Discharge |
Discharge modes | CC, CV, CCCV, CP, CR | |||||||||
| Cut-off condition | Voltage, Current, Time, Capacity, Energy | ||||||||||
|
Pulse |
Charge | CC, CP | |||||||||
| Discharge | CC, CP | ||||||||||
| Min pulse width | 500ms | ||||||||||
| Pulse counts | Up to 32 | ||||||||||
| Chg and Dschg switch | A pulse working step can realize continuous charge switching, or continuous discharge switching; (Charging to discharging switch is not supported) | ||||||||||
| Cut-off condition | Voltage, Time | ||||||||||
| DCIR | Supported | ||||||||||
|
Cycle |
Max cycles | 65535 | |||||||||
| Max steps | 254 | ||||||||||
| Cycle nest | 3 | ||||||||||
|
Protection |
Safety protection |
● Power-failure data protection | |||||||||
| ● Offline operation mode | |||||||||||
| ● User-defined protection conditions, such as upper and lower limited current/voltage, delay time, temperature, etc. | |||||||||||
| Channels feature | Independent pairs of closed loop for constant | ||
| Channels control mode | Independent control | ||
| Data acquisition method | Kelvin connection | ||
| Noise | <55dB | ||
| Database | MySQL | ||
| Communication | TCP/IP | ||
| Operating system | Windows 7/8/10 64bit | ||
| Data export | EXCEL, TXT, CSV, PDF, Plot/Graph | ||
| Min. disk drive | 500GB | ||
| Communication port | Ethernet port | ||
| Leak Current | <5μA | ||
| Channels per unit | 8 | ||
| Operation and storage environment requirement | |||
| Items | Values | ||
| Operation environment temperature | 0℃~40℃ (When the temperature is 25±10℃, the accuracy offset caused by temperature is less than 50ppm /℃) | ||
| Storage environment temperature | -10℃~50℃ | ||
| Operation environment humidity | ≤70% RH(no moisture condensation) | ||
| Storage environment humidity | ≤80% RH(no moisture condensation) | ||
| Clamps and dimensions | |||
| Items | Values | ||
| Clamps pictures
(Pictures just for reference) |
![]() |
OR | |
| Dimensions(W*D*H)(mm) | 3U19”,483*404*130(mm) | ||
| Tester pictures | ![]() |
||